Double Tuned Filter Capacitor Loaded & Capacitor Coupled
(select tank inductor)
Given:
f
o
center frequency
MHz
del f
3db
bandwidth at 3db points
MHz
R
s
source impedance
Ohms
R
L
load impedance
Ohms
L
p
tank inductance
H
q
1
=
k
12
=
Q Bandpass
Q Filter
Coupling Coefficient
Dynamic Resistance
Ohms
Node Capacitor
F
Coupling Capacitor
F
Source side Load Capacitor
F
Adjusted Source side Tank Capacitor
F
Load side Load Capacitor
F
Adjusted Load side Tank Capacitor
F
Graph center frequency
MHz
Bandwidth centered about f
c
MHz
db scale from 0db to
-10
-20
-30
-40
-50
-60
db